To determine the length of the battery, you need to find out what conditions are paramount for a certain room. In any circumstances, the calculation of the number of sections of heating radiators is made personally and will depend on:
The volume of the room. The height of the ceilings plays the main role.
The area of the room at the usual height.
A more detailed calculation is made, given the unification of the first 2 points.
Calculation of calculation needs to know what heat output 1 part. All normative signs of heat are taken into account in SNiP, for example:
The type of structure
Heat consumption for 1m3
Panel houses
41
The current structure with insulated double -glazed windows and walls
34
Example: room “5-10 m, area S = 50m2.Ceiling height “3 m, room volume V = 50-3 = 150m3.The house is panel, we calculate the desired power: 150-41 = 6150W. Cast iron radiators, heat return 1 part = 140 watts.6150: 140 = 43.9, which means that for the dwelling you will need 44 cast -iron parts. Basically, manufacturers overst the heat of the heat of radiators, and therefore should take a stock +20.For ordinary ceiling height, the number of radiators is considered to be the area of the room. In such conditions, the average feature “Distance of heat 1 part = 100W is accepted. Example: S rooms = 50m2 x 100 (average feature): 140W (nominal sign of heat transfer of the battery) = 35.7 = 36 sections.
How to definitely calculate the number of sections:
For a more specific calculation of sections, you need to know a lot of signs than the area or volume of the room. The power of the battery is considered according to the formula: Q = 100W/m2 x d1 x D2 x D3 x D4 x D5 xD6 x D7
Sign
Indicator
Decoding
D1
0.85
Triple double -glazed window
1.00
Double glass package
1.27
Simple glazing
D2
0.85
New heat-insulation from good quality material
1.00
Brick in 2 layers, or brick+ material for insulation
1.27
Poor heat-insulation
D3 – compliance of the area of the windows to the area of the walls
0.80
10%
0.90
20%
1.00
30%
1.10
40%
1.20
50%
D4 – to the maximum cold ambient temperature
0.70
– 10OS
0.90
– 15Os
1.10
– 20OS
1.30
– 25OS
1.50
– 35OS
D5 – the number of walls neighboring with the street
1.10
One
1.20
Corner apartment, 2 walls
1.30
Three
1.40
4
D6 – type of room
0.80
The room is heated
0.90
The attic is heated
1.00
The attic is cold
D7 – ceilings height
1.00
250 cm
1.05
300 cm
1.10
350 cm
1.15
400 cm
1.20
450 cm
Only the correct installation of heating equipment will make it possible to work on heat exchangers on the power stated in the passport.
Video: Exploring the number of sections of aluminum radiators